The operational principle for wYW6Oofiling liuid level detector is while the filing liquid level raised up,the feedback radiation intensityfrom low energy photonic source also changed in accordant,from the feedback signalthe liquid level can be identified,so that the filingliquid level can be controlled accurately.This technology is highly advancein the world,since it solved the weighting problem in fastrunning fling line,therefore it has been widely used in Food,Medicine,and Chemical(liquid type)automatic iling line.
Main technical parameters:
Line speed: ≤ 1.8/ms,50mm diameter Can max speed is 1200Pcs/min
Dynamic container resolution ratio: ± 2mm (foam and vibration will effect the accuracy of detection)
Static liquid level accuracy: ≤0.5mm (water)
Static liquid level accuracy in 8 hrs: 0.15mm (water)
Unqualified rejection rate: ≥99% (detecting speed at 1200pcs/min)
Temperature tolerance:in the temperature range of 0~40℃,the tolerance is ≤0.25mm at testing reference temperature 20℃
Working condition: the minimum time gap is 10ms, also the conveyor must be running at stable condition (any non-steady running wil effect the measure accuracy)
Working environment: temperature 0~40°℃, humidity no less than 95%
Power source: 220V ± 20V,50Hz
Power:≤150w
Size:530mm×150mm×350mm